A centered moving average uses information from both sides of its timestamp
A smoothed curve can look as though it reacts at the same moment as the original record. That appearance depends on where each average is placed on the time axis. Two curves using the same number of values can have different information available at the timestamp printed beneath them.
The distinction is simple but important: a centered average uses neighboring values on both sides, while a trailing average uses the present value and earlier values. Their labels describe different rules, not two names for the same calculation.
Start with the samples that enter one value
Consider a five-point average assigned to sample ten. A centered version uses samples eight, nine, ten, eleven and twelve. A trailing version uses samples six, seven, eight, nine and ten. Both divide a sum of five values by five, but the sums are built from different parts of the record.
At the arrival of sample ten, samples eleven and twelve are not yet available in a live stream. The centered result assigned to sample ten can therefore be calculated only later, unless those later values are supplied by some separate model. A calculation using predicted values would be a different procedure and should be named accordingly.
For an equally spaced record with one second between samples, the centered result needs two additional seconds of observations. Its displayed timestamp can still be ten, but its availability time is twelve. Those are two different pieces of timing information.

A step makes the distinction visible
Imagine a record that is zero through sample nine and one from sample ten onward. The five-point centered average assigned to sample eight already includes sample ten, so its value is 0.2. Its values at samples nine and ten are 0.4 and 0.6.
The trailing average stays at zero through sample nine. At sample ten it becomes 0.2, then rises to 0.4 at sample eleven and 0.6 at sample twelve. These values follow directly from counting how many ones enter each five-value window.
Nothing in the centered calculation anticipated the step before it happened. The record was processed with later observations and the results were placed at earlier timestamps. On a completed chart, that placement can make the transition look earlier than a procedure operating only on available observations could have shown it.
Availability is not the same as alignment
An offline analysis may deliberately use a centered window. When the goal is to describe a completed record with balanced neighbors, that is a clear and useful choice. It becomes confusing only when the displayed result is described as though it had been available immediately at every timestamp.
A trailing window has a different interpretation. It can be updated from observations already received, but its response to a change is spread over later samples. Moving its plotted values backward can change their visual alignment without changing when those values could originally be calculated.
A report should therefore separate the time assigned to a result from the time at which all its inputs become available. This distinction is often more informative than saying that a curve is simply delayed or undelayed.
The edges need their own rule
Near the beginning or end of a finite record, a full centered window may not fit. Software may shorten the window, return an unavailable result, or use a stated extension rule. These choices change which observations enter the average and sometimes change the number of terms in its denominator.
MATLAB's movmean documentation, for example, describes centered windows for odd scalar window lengths and a default that shortens windows at the endpoints. It also provides an explicit backward-and-forward window specification. Reading those details is necessary before assuming that every point uses exactly five observations.
Even window lengths deserve attention too. There is no single middle sample in a group of four. The software must adopt an alignment convention, and that convention belongs in the description when timing matters.
Describe the rule before interpreting the curve
A useful description gives the window length, spacing of observations, backward and forward reach, endpoint handling and timestamp convention. For irregular observations, it also says whether the window is defined by a count of samples or by an interval of time.
Smoothing then becomes a reproducible operation rather than a visual effect. The question is no longer whether the line looks prompt, but which observations support each point and when those observations were available.
Academia Master Trader shares educational material about signals, scales and measurement at academiamastertrader.com.br.