A photodetector bandwidth describes modulation, not the optical carrier frequency
A photodetector can respond to visible or infrared light while its electrical output bandwidth is only a few megahertz. Those specifications describe different parts of the measurement. They do not imply that the detector must reproduce every oscillation of the optical electric field at its output.
The wavelength response tells us which light can produce a useful detector response. The electrical bandwidth tells us how rapidly a variation in the detected optical power can be followed under stated conditions. Keeping these two questions separate makes a detector specification easier to read.
Light can carry a slower variation
Consider an optical beam whose power is varied sinusoidally. The optical field oscillates at its carrier frequency, while the power envelope has its own modulation frequency. A direct power detector produces an electrical signal associated with the detected power variation.
The detector does not need an electrical output at the optical carrier frequency to follow that slower modulation. It does need appropriate sensitivity at the optical wavelength and enough electrical bandwidth for the power changes of interest.
These are independent checks in a specification. A detector with sufficient electrical bandwidth can still be unsuitable at a wavelength outside its useful spectral response. A detector that is sensitive at the chosen wavelength can still be too slow for a particular modulation.

A bandwidth value needs a reference level
A common electrical specification is the three decibel bandwidth. At that frequency, electrical signal power has fallen to about half its reference value. For the same load impedance, signal power is proportional to voltage amplitude squared.
The voltage amplitude at the three decibel point is therefore about 0.707 of its reference amplitude, not one half. The same square law applies when the signal is expressed as current into a fixed resistive load.
This distinction concerns the electrical signal power in the output measurement. It should not be confused with the statement that photocurrent is proportional to incident optical power in an appropriate linear operating range.
A first order example shows what the corner means
For illustration, consider an ideal first order low pass response with a corner frequency of 10 megahertz. Normalize its low frequency electrical amplitude response to one.
At 1 megahertz, the amplitude response is approximately 0.995. At 10 megahertz, it is approximately 0.707. At 100 megahertz, it is approximately 0.100. The response rolls off gradually rather than falling abruptly to zero at the stated bandwidth.
These numbers describe the chosen model, not a commercial detector. Real devices can have more complicated response shapes. A single bandwidth number does not fully specify the magnitude or phase response across all frequencies.
Rise time adds a time domain view
For a first order response, the time taken for a step response to rise from ten percent to ninety percent is approximately 0.35 divided by the three decibel bandwidth. A bandwidth of 10 megahertz gives a rise time of about 35 nanoseconds in that model.
That relationship is useful only with its definition and response assumptions attached. It does not establish the exact rise time of every detector that lists the same bandwidth. Different response shapes and measurement conditions can change the relationship.
The optical source, detector electronics, cable and recording instrument can all contribute to the measured waveform. A slowly rising recorded edge does not, by itself, identify which part of that chain limits the measurement.
The lower frequency limit also matters
Not every detector system responds down to constant optical power. An AC coupled output can suppress the steady component and very slow variations. Its useful frequency range then has a lower limit as well as an upper one.
A signal that appears small or absent can therefore require a check of coupling and frequency response before any conclusion about the incident light. The relevant specification is the response of the complete detection arrangement under the conditions used.
A useful record keeps the optical wavelength range, electrical response range, reference level, load and rise time convention together. It also distinguishes an illustrative low pass model from measured device behavior.
The reading rule is simple: optical wavelength sensitivity answers which light can be detected; electrical bandwidth answers which power variations the output can follow. Neither number replaces the other.
Academia Master Trader shares educational explanations with clear definitions and worked examples. Explore our structure at academiamastertrader.com.br and continue learning with Aprenda.